0102030405
Elevator Door Controller Inverter ThyssenKrupp RCF1 WITTUR SELCOM Elevator Door machine Encoder
DESCRIPTION
RCF1 door controller uses buttons and display to adjust and set parameters of the device. The device has
4-digit display with the following meanings (from left to right)
First digit: parameter type selection
Second digit: parameter number
Third and fourth digits: parameter value
Use 8 buttons to adjust parameters, and their functions are as follows:

SPECIFICATION
| Button | Function | |
| +- | 1&2 | Parameter type selection: U = speed A = torque I = position - = operation mode/door system parameter || = output type command/encoder output signal type |
| +- | 3&4 | Select the phase of the speed curve in the door opening and closing cycle, or the door closing and opening cycle |
| +- | 5&6 | Parameter value adjustment In "self-learning mode", press and hold button 5 to open the door. In "manual mode", issue the "open door" or "close door" command |
| ←┚ | 7 | Store the changed parameters (press and hold the button for at least 2 seconds until the screen flashes once) |
| # | 8 | Insert the factory set value (press and hold the button when starting the device) |
| ←┚ & # | 7&8 together | Working mode/parameter setting mode interchange (press and hold 2 buttons for more than 2 seconds) |
| - & ←┚ | 2&7 together | Activate self-learning mode. |